4.7 Preparing the Hardware for CP4000 (AMD Opteron) Systems
Follow the procedures in this section to prepare each node before installing and configuring the
HP XC System Software. See the following sections depending on the hardware model:
4.7.1 Preparing HP ProLiant DL145 Nodes
On an HP ProLiant DL145 server, use the following tools to configure the appropriate settings
for an HP XC system:
BIOS Setup Utility
Intelligent Platform Management Interface (IPMI) Utility
shows the rear view of the HP ProLiant DL145 server and the appropriate port
assignments for an HP XC system.
Figure 4-11 HP ProLiant DL145 Server Rear View
PC I-X 13 3
Po
w
er
The callouts in the figure enumerate the following:
1.
The console Ethernet port is the connection to the Console Switch (branch or root).
2.
If a Gigabit Ethernet (GigE) interconnect is configured, this port is used for the interconnect
connection. Otherwise, it is used for an external connection.
3.
NIC1
is the connection to the Administration Switch (branch or root). It corresponds to eth0
in Linux if there are no additional optional Ethernet ports installed in expansion slots. On
the HP ProLiant DL145 server, NIC1 is the port on the right labeled with the number 1.
Setup Procedure
Perform the following procedure from the BIOS Setup Utility for each HP ProLiant DL145 node
in the hardware configuration:
1.
Use the instructions in the accompanying hardware documentation to connect a monitor,
mouse, and keyboard to the node.
2.
Turn on power to the node. Watch the screen carefully during the power-on self-test, and
press the F10 key when prompted to access the BIOS Setup Utility.
4.7 Preparing the Hardware for CP4000 (AMD Opteron) Systems