Testing AMPS Base Stations
Transmitter Frequency Error/Offset and Power Test
Transmitter Frequency Error/Offset and Power Test
This test compares the measured center frequency of the base station to 
the AMPS channel standard. The resulting difference is the frequency 
error (also called the frequency offset). The measurement can be 
displayed in frequency units (Hz, kHz, MHz) or in parts per million 
(ppm). Measurements are made with all modulation turned off.
The transmitter’s power can be measured any time the transmitter is 
keyed, but may not be accurate unless all modulation is turned off. 
Transmitter power may be specified by the manufacturer in units of 
watts (W), milliwatts (mW), dBm, Volts (V), or millivolts (mV).
Prerequisites
The following conditions must be met before testing:
❒ The Test Set is turned on and Preset was pressed to establish a 
known instrument state.
❒ You have configured the Test Set for channel or frequency tuning as 
necessary (
❒ You have specified any gains or losses in your test system (
Begin Testing
1. Turn off the base station’s RF transmitter. A transmitter can be 
damaged if it is not transmitting into a specified load, such as an 
antenna, power amplifier, duplexer, or power meter with a 50
Ω
 
input impedance.
2. Verify that the transmitter’s rated RF power (or the level out of the 
power amplifier if applicable) does not exceed the level printed next 
to the Test Set’s RF IN/OUT connector.
3. Connect the transmitter’s RF output to the Test Set’s RF IN/OUT 
port.
4. Turn off any modulation signals to the base station.
• Turn off the SAT tone.
• Turn off any data (digital) modulation signals.
• Turn off any audio (voice) modulation signals.
5. Press the 
RF Anl
 key to access the RF ANALYZER screen.
6. Enter the transmitter’s 
RF Channel
 number.
Main Menu