Testing AMPS Base Stations
Transmitter Data Deviation
Transmitter Data Deviation
This test measures the transmitter’s digital data deviation in the 
absence of any other modulating signal.
Prerequisites
The following conditions must be met before testing:
❒ The Test Set is turned on and Preset was pressed to establish a 
known instrument state.
❒ You have configured the Test Set for channel tuning (
❒ You have specified any gains or losses in your test system (
Test Procedure
1. Turn off the base station’s RF transmitter. A transmitter can be 
damaged if it is not transmitting into a specified load, such as an 
antenna, power amplifier, duplexer, or power meter with a 50
Ω
 
input impedance.
2. Verify that the transmitter’s rated RF power (or the level out of the 
power amplifier if applicable) does not exceed the level indicated 
next to the Test Set’s RF IN/OUT connector.
3. Connect the transmitter’s RF output to the Test Set’s RF IN/OUT 
connector.
4. Turn off voice modulation to the transmitter.
5. Turn off the SAT to the transmitter.
6. Turn on the data modulation to the transmitter.
7. Press 
Shift
RF Anl 
(AF Anl) to access the AF ANALYZER screen.