Hitachi US7070447-001 사용자 설명서

다운로드
페이지 98
HiSpeed Switch Troubleshooting Guide
12-2
US7070447-001, Rev 01
Draft Level—Hitachi Confidential
In a normal ring operation, an FDDI station captures a free token and transmits 
completely unless the token holding timer (THT) expires.  As the frame traverses 
the ring, every station examines the frame and checks for errors.  When the 
destination station receives the frame, it copies the frame into its buffer, sets the 
error, AR, and FC indicators and places the frame back onto the ring.  Finally, the 
frame is returned to the sending station where it is stripped off the ring and the 
token is released.
Station Management (SMT) unique to FDDI, detects, isolates, and recovers 
network faults on the ring.  The HiSpeed switch participates in the ring recovery 
process as a function of SMT.  Built-in timers are used by all stations to ensure 
timely transmission of data across the ring.  Beacon frames indicate that a logical 
problem has occurred and the fault domain is identified.  Given its error detection 
and recovery mechanisms, FDDI is considered to be highly reliable and is widely 
employed as a backbone for local and campus area networks.
HiSpeed FDDI Uplink
Figure 12-2.
FDDI Uplink Module installed in an HS150
LEDs
Optical Bypass
Connector
Port B
Port A