FDDI Concepts
US7070447-001, Rev 01
12-7
Draft Level—Hitachi Confidential
 Problem:
I’m having a communication problem with Platelike over 
FDDI
.
 Solution:
Use the following solutions:
 Verify that you are running firmware version 1.3.28 or above.  
In the CLI, enter the 
‘vsys’ 
command.  If not, upgrade 
firmware on the switch. Refer to HiSpeed’s User Manual for 
further instructions on how to upgrade the switch.

Verify that all IP addresses, subnet masks, and gateways are set 
correctly on the VLANs and any attached devices.
 Problem:
Cannot ping another VLAN over FDDI.
 Solution:
Use the following solutions:

Verify that all IP addresses, subnet masks, and gateways are set 
correctly on the VLANs and any attached devices.
 Verify that all routes are learned using 
‘vir’
. If not, ensure that 
RIP is active on all VLANs.
 Problem:
The FDDI port does not wrap or unwrap (go back into a ring) under 
high traffic loads when the cable is removed/attached.
 Solution:
This is a known issue and currently there is no fix is available.  Resetting 
the switch will re-initialize the switch back into the ring.
 Problem:
FDDI performance is slower from FDDI through Ethernet than 
from Ethernet through FDDI
.
 Solution:
There is about 15% difference in the FDDI to Ethernet performance.  This 
is likely the result of employing ARL lookups in software, rather than 
hardware.  There are currently no plans to improve the FDDI through 
Ethernet performance.
 Problem:
I cannot ping to some stations via FDDI.
 Solution:
There was a problem in the Hardware Type within the arp packet 
generated by the HS150.  This problem was fixed with 1.4.4.  Upgrade 
your switch the latest version of code.  Refer to HiSpeed’s User Manual 
on further instructions on how to upgrade the switch.