Hitachi ET 18DM 사용자 설명서

다운로드
페이지 44
English
10
Lamp indications
Meaning
Lights
Charging time
Lights red
continuously
Charging complete
30 minutes
in about 30 minutes
Charging time
Lights
Lights
Charging complete in
20 minutes
orange
 continuously
about 20 minutes
Charging time
Lights
Charging complete
5 minutes
Lights green
continuously
 
in about 5 minutes
Cannot charge
Lights 0.3
because battery
High temp
Flashes red
seconds/
temperature is high.
standby
off 0.3 seconds
(Charging begins
 automatically when
 temperature drops.)
Flashes red
Lights 0.5
Using power source
Charging
/orange
 seconds/off 0.5
output. (After power
standby
/green
 seconds
 source output, charging
begins automatically.)
Lights 0.5
Before
Flashes red
seconds/off 0.5
Plugged into
charging
seconds
 power source.
Charging status
After charging is
lamp (red/
Charging
Lights green
Lights
complete, battery
orange/green)
complete
continuously
activation (trickle
charge) begins.
Lights 0.1
Charging
Flickers
seconds/off 0.1
Malfunction in the
impossible
orange
seconds
battery or the charger.
Table 2
Lamp Indications
䡬 Regarding the temperature of the rechargeable battery.
The temperatures for rechargeable batteries are as shown in the table below, and
batteries that have become hot should be cooled for a while before being recharged.
Table 3
Rechargeable batteries
EB9S, EB9B, EB12S, EB12B,
EB1220BL, EB14B, EB18B,
EB1820, EB1820L
EB1830H, EB1830HL
Temperatures at which the battery can be recharged
–5°C — 60°C
–5°C — 55°C
Charging time
lamp (red/
orange/green)