Gossen R2601 사용자 설명서

다운로드
페이지 40
GOSSEN METRAWATT GMBH
32
4.4 Equipment specifications
The equipment specifications in main group 3 of the parameter index among others include marking identification, software version and some configurations.
4.4.1
Table of equipment specifications 
PI
Parameter
Format
Unit
Setting range
Remarks
30h
Equipment marking
8 bits
26h
Read only
31h
Marking identification
8 bits
Bit field
(4.4.2)
Read only
32h
Configuration
Sensor unit, continuous output
8 bits
(4.4.3)
CnF1, 4th digit
33h
Sensor type, B marking
2x8 bits
(4.4.4)
CnF1, 3rd digit
35h
Software version
8 bits
e.g. 18h = version 1.8
Read only
36h
Configuration of alarms 1 / 2
8 bits
Bit field
(4.4.5)
CnF1, 1st digit
CnF2, 1st digit
39h
Configuration of
switching outputs I / II
8 bits
Bit field
Value
I
II
Read only
(DIP switch)
00h
08h
10h
18h
Transistor
Relay
Transistor
Relay
Transistor
Transistor
Relay
Relay
3Ah
Continuous signal Cont
8 bits
0 = actual set point
1 = Cool reg. ratio (instead of II)
Only active, if PI = 32h 
set to
≥ 8
3Fh
OEM version number
8 Bit
0 = no OEM version
Read only