3.7.2 P
RINTER
 F
ONT
 C
OMMANDS
 – C
OURIER
 C
HARACTER
 S
ET
:
Font Name
Character size (W x H)
Command String
24 CPI normal
8x23
ESC+'k'+'5'
21 CPI normal
9x23
ESC+'k'+'4'
19 CPI normal
10x23
ESC+'k'+'3'
16 CPI normal
12x23
ESC+'k'+'2'
12 CPI normal
16x23
ESC+'k'+'1'
13 CPI rotated
14x16
ESC+'k'+'0'
3.7.3 P
RINTER
 F
ONT
 C
OMMANDS
:  
Command String
Printer Action
ESC - ‘F’ – 1
Selects International character set
ESC - ‘F’ – 2
Selects PC Line Draw character set
ESC - ‘U’ - ‘1’
Enable emphasized print.
ESC - ‘U’ - ‘0’
Disable emphasized print.
3.7.4 P
RINTER
 G
RAPHIC
 C
OMMANDS
:
Command String
Printer Action
ESC - ‘a’ – n
Select dot line spacing between printed lines.
ESC - ‘J’ – n
Graphic Line Feed command
ESC - ‘P’ - ‘#’
Select Online mode, characters printed as received.
ESC - ‘P’ - ‘$’
Select Buffer mode, characters are printed on (^ D)
ESC - ‘V’ - n1 – n2
8-bit Graphic command
ESC - ‘v’ - n1 – n2
RLE Compressed Graphic command
3.7.5 M
AGNETIC
 C
ARD
 R
EADER
 C
ONTROL
 C
OMMANDS
:
Command String
Printer Action
ESC - ‘M’ - ‘nnm’ - Cr
Select MCR  with (nn) auto timeout
ESC – ‘C’
Cancel MCR read process
3.7.5.1 S
MART
 C
ARD
 R
EADER
 C
ONTROL
 C
OMMANDS
 (
WHEN
 SCR 
IS
 
INSTALLED
):
Command String
Printer Action
ESC - ‘M’ - ‘nn’ - ‘7’- Cr
Select SCR in direct mode with Serial RS232. 
(nn) is the auto timeout of the SCR.
ESC - ‘M’ - ‘nn’ - ‘8’- Cr
Select SCR in PassThru mode with BT/802.11 or IrDA on.