Maintenance for Your Drive
G SPEED
eS
PRO
WARNING: Make absolutely sure that you remove the correct drive as indicated in the 
steps below. 
REMOvING ThE WRONG DRIvE CAN RESULT IN ThE LOSS OF ThE ARRAY AND ALL 
OF ThE CONTENT STORED ON G-SPEED ES PRO.
 
5.  The failed drive’s LED will begin to blink in the  
G-SPEED eS Pro enclosure, making it easy to  
identify which drive needs to be replaced. Be  
certain to remove the correct drive, as removing  
the wrong drive could cause data loss. 
 
NOTE: It is possible the failed drive will be completely 
offline. In this case, the drive’s Activity LED will be com-
pletely turned off, indicating the failed drive.
6.  Remove the failed drive by inserting the provided key into the Lock hole and  
sliding the drive out of the enclosure.
7.  Replace the failed drive with a new disk module and secure in place. Once the drive 
has spun up to speed, the ConfigTool will indicate that the array is rebuilding. The 
rebuild time is approximately 1 hour per TB. 
Once the rebuild is complete, G-SPEED eS Pro is back to normal, protecting your valu-
able data once again.
NOTE: Replacement and/or extra G-SPEED eS Pro disk modules are available for pur-
chase online at: 
www.g-technology.com/Products/g-speed-es-pro.cfm
Drive Activity LED