Eventide DJ Equipment DSP4000B+ 사용자 설명서

다운로드
페이지 99
The Harmonizer
 Programmer’s Manual
 
 
The Harmonizer
 Programmer’s Manual 
Page 43 of 97 
Release 1.2.1
 
 
 
 1999 Eventide, Inc. 
 
Textknob Module 
The textknob module 
creates a multiple choice 
selection in a single line by 
half screen width area of a 
PARAMETER
 area menu page.   
 
The choices appear in place 
of the %s in the menu 
statement.  The
 
8 char name is 
only used if the module’s 
userobject is connected to the 
head
 module.  The control 
output reflects which 
selection is made.  If the 1st 
selection is made the output 
will equal 0.  If the 3rd 
selection is made, the output 
value will equal 2.  
C
ONTROL 
S
IGNAL 
M
ONITORS
 
Just as “parameter adjuster” modules are used to generate control signals and are displayed as parameters in 
PARAMETER
 area menu pages, control signal monitor modules monitor the value of control signals and may 
be displayed on those same menu pages.   
Graphical Control Signal Monitors 
There are five different monitor modules.  Three of these, the 
hmonitor
, meter, and vmonitor modules, produce 
graphical displays.  The screen to the right 
(taken from the program 
Interface Modules
 from the “
Programming
” bank)
 shows the three 
graphical monitors 
(among others)
 
• 
Each of the graphical 
control signal monitor 
modules has a control 
signal input and four 
specifiers: minimum, 
maximum, name and tag.  
minimum sets the lowest 
value that may be 
indicated by the monitor. 
• 
maximum sets the highest value that may be indicated by the monitor. 
• 
For vmonitor and hmon, the tag specifier is used to generate the text for the monitor. 
• 
For meter, the name specifier is used to generate the text for the monitor. 
• 
The text fields of the monitors may include %f format numeric displays 
(to convey numerical as well as graphical 
information)