MA-5002VZ Power Amplifier
Operation Manual
4.3 Back Panel Controls 
and Connectors
I.
Stereo/Mono Switch
Allows selection of Stereo, Bridge-Mono, 
or Parallel-Mono operation.
J. Compressor Switch
Controls the channel's error-driven com-
pressor. Selections include Off; Fast (4-
millisecond attack, 300-millisecond 
release); and Slow (12-millisecond attack, 
600-millisecond release).
K. Loudspeaker Offset Integration
       Switch
Allows the Loudspeaker Offset Integration 
(LOI) circuit to be enabled or disabled. See 
Section 5.2.4  for more info about LOI.
L. Sensitivity Switch
Three-position switch. Allows the selec-
tion of 26 dB; 1.4V; or 0.775V input 
sensitivity.
M. Power Cord
N. Output Connectors
High-current output block accepts banana 
plugs, spade lugs or bare wire. A detatch-
able output cover, shown in Figure 4.3, 
protects against accidental short circuits 
and dangerous electrical shock. 
DANGER: The outputs can produce 
lethal energy levels! Do not change 
the output wiring unless the ampli-
fier has been off for at least 10 sec-
onds.
Note: Some international models include 
high-current binding posts rather than the 
output block. Figure 4.4 shows the inter-
national binding posts.
4 Operation 
(continued)
Figure 4.2 Back Panel 
Controls and Connectors