Fujitsu Network Hardware V01 사용자 설명서

다운로드
페이지 138
Chapter 4  Troubleshooting  
IP-900 Series 
115 
Code 
Name 
Description 
Details (The part after the * mark is not displayed.) 
I002 
HDMI input down 
HDMI input signal not detected 
 
*I002 
HDMI input down recovery 
Normal HDMI input 
 
I003 
Analog input down 
Analog video input signal not detected 
 
*I003 
Analog input down recovery 
Normal analog video input 
 
I011 
Video input synchronization error 
Video input PLL synchronization error 
occurred 
 
*I011 
Video input synchronization error 
recovery 
Recovered from video input PLL 
synchronization error 
 
I021 
Input data error (*8) 
Count-up  occurred  in  the  performance 
statistics error counter 
#xxxxxxxxxxxxxxxx 
* 64-bit hexadecimal number.  For the meaning of each 
bit, see Table 3-12, "Input data error bit format". 
*I021 
Input data error recovery (*8) 
Recovered  from  count-up  of  the 
performance statistics error counter 
 
E001 
Power error (*1) 
Power failure occurred 
#1  *  Power failure on CNT board 
#2  *  Power failure on COD board 
E003 Temperature 
error 
occurrence (*5) 
Extreme  temperature (shutdown processing 
started) 
*  Details are as follows: 
 #1/#2: Number of the temperature sensor that has 
detected a temperature error 
 t1: Temperature indicated by temperature sensor 1 
 t2: Temperature indicated by temperature sensor 2 
 xxx: FAN rotational speed 
E004 
Flash ROM error (*1) 
Internal flash ROM access error occurred 
/dev/mtd0 to 15 
* Displays the occurrence range of access error. 
E00A 
Flash ROM check sum error (*1) 
Operation data error detected in internal 
Flash ROM 
Software 
bundle software 
configuration 
configuration#1∼#10 
* Displays the occurrence range of check sum errors. 
E010 
FAN error (*2) 
FAN error (low speed) or stopped 
xxxRPS  *  xxx: FAN rotational speed 
*E010 
FAN error recovery (*2) 
FAN speed recovery 
xxxRPS  *  xxx: FAN rotational speed