Solving Problems
3-9
Infrared Data Transfer Is Not Working
3
If you are experiencing problems transferring data over the system’s infrared 
interface, note the following:
• Can the IrDA port on the pen tablet “see” the IrDA port on the other device? A 
direct line-of-sight path must exist between the IrDA port on the pen tablet and 
the IrDA port on the other device. 
• The distance between the two devices must not be more than approximately 3 feet 
or 1 meter.
• The viewing angle from the IrDA port on the pen tablet must not be more than 15 
degrees from a center line between the IrDA port on the pen tablet and the IrDA 
port on the other device. 
• The device with which you are trying to communicate must be compliant with the 
IrDA Standard Revision 1.1. 
Pen Tablet Is Not Responding to the Pen
3
If your pen tablet is not responding to the pen, check the following: 
• Ensure that the pen tip moves freely. Replace the pen tip if it is damaged or 
warped. See “Replacing the Pen Tip” earlier in this chapter. 
• Ensure that the pen battery is in good condition. Replace the pen battery if the age 
or condition of the battery is suspect. See “Replacing the Pen Battery” earlier in 
this chapter. 
• If available, connect an external keyboard to the system to see if it responds to 
keyboard commands. If the system doesn’t respond to the keyboard, the 
application or system may have crashed, and it may be necessary to reset the 
system.
Cursor Is Not Tracking Pen 
3
If the cursor on the screen is not accurately tracking the pen or appears to be 
misaligned with the pen, calibrate the pen. See “Calibrating the Pen” earlier in this 
chapter for details.