Ciprico Rimfire 3880 사용자 설명서

다운로드
페이지 230
User’s Guide
21020285 D
Chapter 3   Hardware Installation
 
Step 4: Apply power and observe LEDs
 Page 3 - 13
Error
Conditions
The amber LED is used to indicate an error condition. These are the conditions 
indicated by the amber LED:
BLINKS
 - This indicates that the adapter has had a self-test failure.
STAYS ON SOLIDLY
 - This indicates that the board has had a catastrophic 
error during operation such as bus error or timeout. The Status port will contain 
an error code that details the type of failure that occurred. These error codes are:
Code
Name
Description
10H
Bad PBIN or SBOUT 
Value
The Command List PBIN or SBOUT value exceeded the 
value set for PBNUM or SBNUM.
11H
State wrong for Start/
Stop Command List 
command
The code is returned under these conditions:
Start Command List
 command issued a command list is 
already active.
Stop Command List
 command issued when no command 
list is presently active.
Command List Channel Attention
 issued when no 
Command List is active.
12H
Target Mode Error
Target Mode Selection Area Read
 Channel Attention 
issued when no selection are was written by adapter.
14H
Software VMEbus 
Timeout
The adapter times each of its VMEbus transfers; it will report 
this if a VMEbus transfer takes too long to complete. This 
can occur for transfers of parameters as well as data.
15H
VMEbus Error Occurred
A VMEbus error was detected while the adapter was 
transferring either parameters or data.
96H
Internal Firmware Error This error code indicates that a Firmware error was detected 
during the execution of a command.
Table 15: Status Port Catastrophic Error Codes