Installation / 
Assemb
ly
9
2009 Fireplaces and Firepits
LTR20091006, Rev. B
www.calspas.com
Connection
Inspect the hose shipped with the unit for damage. Never attempt to 
use damaged or plugged equipment. See your local LP gas dealer for 
repairs. After inspecting the LP hose shipped with the unit, connect the 
end with the female fitting on the hose to the male fitting on the on/off 
gas valve at the end of the hose. Tighten fittings using two wrenches.
When connecting the regulator assembly to the tank valve, hand tight-
en the black QCC-1 nut clockwise. DO NOT use a wrench to tighten. 
See the figure below.
Purge the gas supply line of any trapped air prior to the first firing of 
the unit.
During the initial purging and subsequent lightings, NEVER allow gas 
to remain in the “Open” position without first placing and igniting the 
fire starter.
Locate the hose out of the pathways where people may trip over it or in 
areas where the hose may be subjected to accidental damage.