Chapter 2: INSTALLING THE CSMIM-T1
2-16
CSMIM-T1 Hardware Installation Guide
2.8.3
Reloading EFS Key Value
In the event that the EFS value is lost, follow this procedure to reload the
key. This requires Superuser privileges. If you do not have the correct
access abilities, contact the Network Administrator for assistance. If you
have not stored the key value in a safe place and must contact Cabletron
Customer Support, do so before beginning this procedure.
key. This requires Superuser privileges. If you do not have the correct
access abilities, contact the Network Administrator for assistance. If you
have not stored the key value in a safe place and must contact Cabletron
Customer Support, do so before beginning this procedure.
1.
Telnet to the module.
2.
At the
annex:
prompt, run the
stats -o
command, to check the status
of the module.
3.
Become Superuser. At the
annex#
prompt, enter
show ann opt_key
.
This will show the current option key value in quotations.
4.
Enter the EFS value at the prompt.
5.
Reboot Unit.
6.
At the
annex:
prompt enter
stat -o
command again to check that the
value was accepted.