Post-upgrade tasks
Issue 9.1 June 2006
291
 
To busy out trunks 
1. Busy out trunks that were busied out before the upgrade (see 
To check for translation corruption 
1. Type newterm and press Enter
If you do not get a login prompt and see the following message: 
Warning: Translation corruption detected
 
follow the normal escalation procedure for translation corruption before continuing the 
upgrade. 
To resolve alarms 
1. On the Maintenance Web Interface, under Alarms click Current Alarms to examine the 
alarm log. 
2. If any alarms are listed, click Clear All.
3. Resolve new alarms since the upgrade through Communication Manager using the 
appropriate maintenance reference. 
To re-enable alarm origination
1. Access the server’s command line interface using an SSH client, like PuTTY, and an IP 
address of 192.11.13.6.
2. At the command prompt, type almenable -d b -s y
where
-d b
 sets the dialout option to both (numbers)
-s y
 enables SNMP alarm origination
3. Type almenable (without any options) to verify the alarm origination status.
To back up the system
Using the Maintenance Web Interface, back up the system as you did before the upgrade 