Rack Mount Requirements
You can rack mount your Effects or Editing system. Plan for sufficient space in your rack mount 
chassis to install the following components:
• 
An HP xw9400 system
• 
An AJA OEM-2K breakout box
• 
A Miranda DVI-Ramp
2
• 
A Stone Direct storage chassis (XR model)
• 
Additional Stone Direct expansion chassis (XE model), as required
The form factor units of these components are provided in the following table.
Avoiding Damage from Static Electricity
When installing any hardware equipment, take the following precautions to prevent damage to 
sensitive components from static discharge:
• 
Make sure power is turned off on the component you are working on. It is a good idea to 
unplug components until all other connections are configured.
• 
Always wear a grounded static wrist strap. Attach the strap’s alligator clip to any grounded 
metal surface on the component’s chassis that you are working on. Place the wristband around 
your wrist.
• 
Do not handle any components unnecessarily, particularly boards and cards that slide in and 
out of PCI slots on their parent hardware components.
Grounding Audio Hardware Components
It is important to properly ground your audio components. Otherwise, you may have ground 
loops, or humming in the system. To ensure audio components are properly grounded, use the 
 Unit Conversion
Example
1 Watt = 3.413 BTU
384 Watts = 1228.68 BTU
12000 BTU = 1 Ton of air conditioning
1228.68 BTU = 0.102 Ton of air conditioning
 Component
Quantity
Form Factor
Required Rack Space
HP xw9400
1
5U
5U
AJA OEM-2K breakout box
1
1U
1U
Miranda DVI-Ramp
2
1
1U
1U
Stone Direct storage chassis (XR)
1
2U
2U
Stone Direct expansion chassis (XE) 
(each)
1
2U
2U