TROUBLESHOOTING (continued)
Problem
Possible Cause
Corrective Action
Product is getting stuck 
or conveyor belts stop 
when product is toasting 
(continued).
Not enough voltage, defec-
tive power cord or rocker 
switch.
Check receptacle for correct voltage. See 
Specifications (page 5).
With unit plugged in and rocker switch on, check for 
correct voltage into rocker switch.  If low or zero volt-
age, replace power cord.  If voltage is correct, check 
for correct voltage out of rocker switch.  If low or no 
voltage, replace rocker switch.
Wiring problem.
Check all electrical connections for burns, discolor-
ation or arcing.  Replace all connections or compo-
nents with damaged terminals.  Replace all damaged 
wiring with the same (or higher) rated wire.
Conveyor drive motor inop-
erative or incorrect conveyor 
motor installed on toaster.
To check drive motor:
1. Measure resistance of motor coil.  Replace motor 
if coil measures either open circuit or zero resis-
tance.
2. Mark the drive motor sprocket and count the turns 
per minute.  Correct drive motor speed is nine (9) 
turns per minute for VCT-20; three (3) turns per 
minute for VCT-25; one (1) turn per minute for 
VCT-50.
Conveyor drive chain loose, 
worn or broken.  Loose 
motor drive sprocket.
Check drive chain for kinks, broken or bent links 
or other damage.  Check motor sprocket and drive 
sprockets (on drive shaft); tighten setscrew on flat of 
shaft if required.  Check for damaged/worn sprockets 
and replace as required.
Conveyor cover assy(s). 
not installed, or improperly 
installed.
Install conveyor cover assy(s). 
Conveyor belts installed 
incorrectly.
Install conveyor belt to match diagram in Fig. 8 (page 
11).  Be sure that ends of the hooks are facing down.
Conveyor belt too loose 
or missing links (41 links 
required when new). When 
new, conveyor has 37 large 
links and 4 small links. 
Remove conveyor belt (page 11).  Lay belt flat and 
count links. Replace entire belt if links are dam-
aged. If conveyor belt has too much play, it will jam.  
Adjust belt length as described under Servicing the 
Conveyor Belt (page 11).
Spring tensioner assy(s). or 
tensioner bent or missing.
Replace spring tensioner assy(s). (29, page 22) 
or tensioners (4, page 24) if damaged or loose.  
Replace slide rails (40, page 24 worn or missing.