Chapter 4 - Operation and Administration 
 
BreezeACCESS VL System Manual
 
88 
4.1 
Working with the Monitor Program 
4.1.1  Accessing the Monitor Program Using Telnet 
Connect a PC to the Ethernet port, using a crossed cable. 
Configure the PC's IP parameters to enable connectivity with the unit. The 
default IP address is 10.0.0.1. 
Run the Telnet program. The Select Access Level menu is displayed. 
Select the required access level, depending on your specific access rights. A 
password entry request is displayed. Table 4-1 lists the default passwords for 
each of the access levels. 
 
Table 4-1: Default Passwords  
Access Rights 
Password 
Read-Only public 
Installer user 
Administrator private 
 
 
 
 
NOTE 
Following three unsuccessful login attempts (using incorrect passwords), the monitor program is 
blocked for several minutes. To enable access to the monitor program during that time, the unit 
must be reset via SNMP or by disconnecting/reconnecting power. 
If you forgot the password, type "h" at the Access Level selection prompt. Type “Recover” at the 
prompt to get a challenge string consisting of 8 characters. Contact Alvarion's Customer Service 
and give them the challenge string (after user identification) to receive a one-time password. 
Aftering entering this password at the prompt, the unit will reboot with the default Administrator 
password (private). Three consecutive errors in entering the one-time password will invalidate it 
and block the monitor program. A new challenge string should be used to receive a new one-time 
password. 
Enter your password and press Enter. The Main Menu is displayed as shown 
in Figure 4-1. The unit type and location (if configured), SW version number 
and SW release date displayed in the Main Menu vary according to the 
selected unit and SW version.