Allied Telesis Computer Hardware x900 Advanced Gigabit Layer 3+ Expandable Switches 사용자 설명서

다운로드
페이지 9
Allied Telesis
www.alliedtelesis.com
N
ETWORK
R
ESILIENCY
S
OLUTIONS
| VCStack + Link aggregation
x900 Configuration
log buffered level errors
log host 192.168.10.11
log host 192.168.10.11 level debugging
access-list 1 permit 192.168.10.13
snmp-server enable trap auth nsm
snmp-server community public ro 1
snmp-server host 192.168.10.13 version 2c public
stack resiliencylink eth0
stack 1 priority 1
vlan database
vlan 169-172 state enable
interface port1.0.1
switchport
switchport mode access
switchport access vlan 169
static-channel-group 1
interface port2.0.1
switchport
switchport mode access
switchport access vlan 169
static-channel-group 1
interface port1.0.3
switchport
switchport mode access
switchport access vlan 170
static-channel-group 2
interface port2.0.3
switchport
switchport mode access
switchport access vlan 170
static-channel-group 2
interface port1.0.5
switchport
switchport mode access
switchport access vlan 171
static-channel-group 3
All log messages are sent to a syslog server. Higher-severity
log messages are also buffered on the switch itself
A resiliency link backs up the dedicated stacking link. If the
stacking link fails, communication is maintained to allow
graceful reconfiguration
Use priority to pre-elect the VCStack master switch
Allow read-only SNMP monitoring from one management
station
Create link aggregation groups across the VCStack
members for resiliency. One for servers, and three for
edge switches
Create VLANs.VLAN 169 for servers, and VLANs 170-172
for connectivity to edge switches