Alesis Studio Interface MasterControl 참조 매뉴얼

다운로드
페이지 56
 
37 
 
„  Direct Monitoring   
 
 
 
When the MasterControl’s Direct Monitoring function is enabled, 
the signal you are hearing is taken directly from the MasterControl 
rather than from your DAW.  This allows you and your musicians 
to monitor the audio with no perceptible delay (latency).  Here, you 
can choose whether or not the Direct Monitoring signal will be blended with the signal from the DAW in 
each channel pair.   
 
You can adjust the blend of the Direct Monitoring signal with the 
DAW’s output by turning the DIRECT MON LEVEL knob.  At 0%, you 
will hear only the DAW’s output.  At 100%, you will hear the Direct 
Monitoring signal at an equal volume with the DAW’s output.  In the 
latter case, you may hear the input signal twice, with a short delay 
between each instance (“slapback”).  To hear the Direct Monitoring 
signal alone, simply turn off the input monitoring in your DAW. 
 
„ 
 
Talkback 
    
Pressing the MasterControl’s TALKBACK button will activate the 
built-in microphone above it, which you can use to talk to your 
musicians.  When you select “Yes,” the talkback signal will cause 
the DAW’s outputs to be muted (so talkback can “override” 
whatever else is coming over the headphones or monitors).  When you select “No,” the TALKBACK 
button will have no effect. 
Note: You will not be able to use talkback while recording at 176.4kHz and 192kHz. 
 
„  Talkback Volume   
 
 
 
This setting determines the volume of the talkback signal. 
 
 
„  Optical Port 2 
 
 
 
 
The ADAT 2 / S/PDIF port on the rear panel of the MasterControl 
can accept either ADAT or optical S/PDIF information, which you 
can select here. 
 
„  Footswitch Setup   
 
 
 
When a footswitch is attached to the FOOTSWITCH connection 
on the rear panel of the MasterControl, it can be set to operate on 
the control surface or act as the TALKBACK button. 
 
„  Footswitch Polarity 
 
 
 
 
This setting changes the polarity of a connected footswitch.  The 
default is “Positive On,” meaning the pedal, when pressed, will 
activate or engage whatever it is set to.  Selecting “Negative On” 
will configure it such that it will be on as long as the pedal is not 
being pressed.  
 
„  Send SysEx 
 
 
 
 
 
Access this page to download a SysEx file to the MasterControl to 
change the configuration of its Editable Controls for its various 
Presets.  Select which Preset this will affect by turning the PUSH 
SELECT knob.  You can select any of the 12 Presets or the global 
configuration (“GLOBL"): 
DIR. MON ON 1/2 
 Yes
TALKBACK ON 1/2 
 Yes
TALKBACK VOLUME 
 10%
OPTICAL PORT 2 
 ADAT
FOOTSWITCH
 
SETUP 
Control Surface 
FOOTSWITCH
 
POLAR 
 Positive On 
SEND SYSEX PRE 1 
 Press to send 
Note: At 176.4kHz and 
192kHz, you can only use 
the MasterControl’s direct 
monitoring function on the 
Output Source A – or 