ADIC SNC 5100 사용자 설명서

다운로드
페이지 228
Setting the Time and Date
101
6-00020-02
SNC 5100
Setting the Time and Date
Setting the Real Time Clock
Step 1.
Use the 
rtcDateSet
 command to manually set the Real Time 
Clock. 
For more information, see the 
Example:
SN60023 > rtcDateSet 2001,1,26,5,9,30,00
value = 0 = 0x0
SN60023 >
Step 2.
Use the 
dateSetFromRTC
 command to set the SNC 5100’s RTC as 
the source of date display. 
For more information, see the 
Example:
SN60023 > dateSetFromRTC
value = 0 = 0x0
SN60023 >
Step 3.
Use the 
tzSet
 command to set the timezone. EST is used in the 
example for Eastern Standard Time. 
-12
CRC Error - degraded link
-13
Timeout Error
-14
File size error - file size is different than it was supposed to be
-15
Invalid file type
-16
Too many retries - degraded link
-17
Position Error - file data has been lost
Table 12: Zmodem Status Codes
Status
 Code
Description