ADIC SNC 5100 사용자 설명서

다운로드
페이지 228
Diagnostic Commands
193
6-00020-02
SNC 5100
The 
fcSlotTest
 command performs a confidence test on a Fibre Channel 
slot. Substitute for 
x
 the Fibre Channel slot number you want to test. This 
command can be used to test the slot or the cable.
The following example code shows the display for a test Fibre Channel slot 1.
diagmode > fcSlotTest 1
FC 1 [##########] Iterations 72 Errors 0 - PASSED
Fibre Channel Port 1 returns PASSED
value = 0 = 0x0
diagmode > fcSlotTest 2
FC 1 [##########] Iterations 72 Errors 0 - PASSED
Fibre Channel Port 2 returns PASSED
value = 0 = 0x0
The following outputs are examples Fibre Channel port tests that were not 
successful. If your test was not succesful, return to the MAP that sent you here.
Unsuccessful Fibre Test 1:
diagmode > fcSlotTest 1
FC 1 [##########] Iterations 7799 Errors 7799 - FAILED
Fibre Channel Port 1 returns FAILED
value = -1 = 0xffffffff = pNullDmaDesc + 0xfe4ea9f7
Note: If the Fibre Channel “link” LED does not come on, the test will not 
pass. 
Unsuccessful Fibre Test 2 (cable not plugged in):
diagmode > fcSlotTest 1
FC 1 [##########] Iterations 37 Errors 37 - FAILED
Fibre Channel Port 1 returns FAILED
value = -1 = 0xffffffff = pNullDmaDesc + 0xfe4ea9f7
scsiChannelTest (x,y)
The SNC 5100 must be in diagnostic mode to use this command and a SCSI 
cable must be connected between two SCSI channels.
The 
scsiChannelTest
 command performs a confidence test on a pair of 
SCSI channels. Substitute for 
and 
y
 the SCSI channel numbers you want to 
test. Parentheses are optional. This command can be used to test the SCSI 
interface or the SCSI cable.