ADIC SNC 5100 사용자 설명서

다운로드
페이지 228
SNC 5100 
16
Supported Devices
6-00020-02
Supported Devices
The architecture and implementation of the SNC 5100 software has full 
SCSI-2 and SCSI-3 target and initiator support. The SNC 5100 has support for 
disk, tape, and medium changer devices. The product supports all these devices 
with the same firmware. Multiple target device type drivers coexist to support 
different device types.
www.adic.com
.
Operating Specifications
This section contains the physical, electrical, and environmental specifications 
for the product. 
The enclosure is designed for strength, durability, and electromagnetic and 
radio frequency interference (EMI/RFI) immunity. 
The external dimensions are: 
• 1.61” high
• 12” deep
• 8.61” wide
• weight: 2.70 kg (~5.93 lb.) with bezel
In order to provide a safety margin and permit adequate cooling, the unit is 
fitted with a 12 VDC tach-output blower. Should temperatures exceed 
specifications, an environmental alarm violation is sent and logged in a 
non-volatile location immune from user erasure, permitting environmental 
causes of failure to be determined.
Operating Environment
• Operating Temperature: 10
°
 C to 40
°
 C 
• Storage Temperature: -40
° 
C to 65
° 
• Humidity: 10%-90% Operating, Non-Condensing
     5%-95% Non-operating, Non-Condensing