SCSI Channel MAP
57
6-00020-02
SNC 5100
Examine SCSI Connectors
Caution
Before removing a SCSI cable, all I/O to the SNC 5100 must be 
stopped and the SNC 5100 must be turned off.
Step 1.
Inspect each connector to find out if pins were bent when the 
connector was attache
d.
Step 2.
Replace any cables that have bent pins.
Step 3.
 If you did not have to replace or re-secure a SCSI cable, go to 
Step 4.
If you replaced or re-secured a SCSI cable, turn on the SNC 5100. 
Step 5.
After it finishes booting, enter the 
scsiShow
 command from the 
service terminal.
For more information, see the 
Step 6.
Compare the list of attached devices with the physical devices. 
If not all of the physical devices are shown, go to 
If all of the physical devices are shown, go to 
SCSI Health Check
Step 1.
Perform a Health Check. 
For more information, see “Perform Health Check” on page 46.
Step 2.
Check the Event Log for SCSI errors.
Step 3.
Perform a component check.
Step 4.
If errors are still indicated, go to 
.
If no errors are reported, exit this MAP.