Return Values
VSCMD_ConnectQuery_SetDefaults
 returns:
VSE_TRUE
 - Successful execution.
VSE_FALSE
 - API failure - An appropriate error code is set 
in 
VSG_Error
.
VSE_ERR_BADFIELD
 - An invalid parameter was 
specified.
VSE_ERR_BADSIZE
 - The value passed for a string 
parameter exceeds the maximum allowable length for that 
parameter.
VSID_STATUS_WAIT_FLAG 
(VST_STATUS_WAIT_FLAG)
Flag indicating whether the API software waits 
for final status from VolServ (or times-out) for 
Connect Query commands. Valid options are 
VSE_TRUE
 (API software waits for final status) 
and 
VSE_FALSE
 (API software does not wait 
for final status). Also determines whether the 
API software operates in synchronous mode 
(
VSE_TRUE
) or in asynchronous mode 
(
VSE_FALSE
). The default 
VSID_STATUS_WAIT_FLAG
 value is 
VSE_TRUE.
VSID_TIMEOUT_VALUE (VST_TIME_OUT)
The total wait time for a command is 
(
VSID_RETRY_LIMIT
 plus 1) multiplied by 
VSID_TIMEOUT_VALUE
. The default time-out 
value is 120 seconds.
VSID_USER_FIELD (VST_USER_FIELD)
Value to be put in 
USER_FIELD
 for Connect 
Query commands. 
USER_FIELD
 is a 
16-character field provided for user 
information. Information entered in this field is 
echoed back to the user in every status 
message returned for Connect Query 
commands. Neither the API software nor 
VolServ uses 
USER_FIELD
.
Parameter Type