DVDO iScan Pro Progressive Scan Display Interface 사용자 설명서

다운로드
페이지 26
Silicon Image, Inc.
 
 
iScan Pro User Manual 
 
 
 
24 
  
Modifying Composite Sync Jumper 
Setting 
1)  To configure the unit to output Composite Sync, locate the 
connector labeled “J-10”, as shown. A plastic jumper 
should already be straddling the two pins closest to the 
“NORMAL” label. 
2)  Move this jumper from its current position to the two pins 
closest to the “CSYNC” label as shown below.  
 
 
 
 
 
Modifying Sync-on-Green Jumper Setting 
1)  To configure the unit to merge sync with Green, locate the connector labeled “J8”, as shown above. 
There should already be a jumper on two of the pins, closest to the label “NORMAL.” 
2)  Move this jumper from its current position to the two pins closest to the “SYNC GREEN” label as 
shown above. 
 
Reassembling the iScan Pro 
 
1.  Push the PC board back into the unit 
slowly, being careful that the bottom slots in 
the housing are used to guide the board and 
that the front indicators appear through the front panel. Verify that the front panel switches 
protrude fully through the panel. 
2.  Replace the copper grounding clips so that they tuck between the power connector, the 
component connector, the output connector and the PC board and so that it makes contact 
with the metal enclosure. 
3.  Place the EMI gasket and the back panel over the connectors and make sure that it is flush 
with the sides of the housing. 
4.  Screw the two screws into the rear panel of the unit.
 
You may want to attach a note to the iScan Pro specifying which internal setting you have changed. 
This will be helpful at a later time when you may need to reconfigure your iScan Pro to work with a 
new display device. 
 
Front of board 
Rear of board