Dot Hill Systems II 200 FC 사용자 설명서

다운로드
페이지 210
Chapter 6 Checking LEDs
6-9
The I/O expansion module LEDs and their color definitions are shown in Table 6-5.
Note – 
An SFP link status (L) LED is off if there is no connection or a failed 
connection to this SFP.
6.3.3
Power Supply and Fan Module LEDs
The following figure shows the AC power supply and fan module.
Table 6-5  I/O Expansion Module LEDs
LED
Purpose
LED Color Definition
Activity
I/O activity of host 
and disk ports
Off – Not busy (no I/O activity)
Blinking green – Busy (active I/O)
I/O module
Status of I/O 
module
Solid green – Power-up successful and SES 
chip has successfully read on-board 
temperature and voltage sensors
Amber – Expansion unit powering up, or 
failed voltage or temperature sensor
Off - Expansion unit is not powered up
SFP link (L)
SFP link status
Solid green – Active good FC Connection
Off – Empty or failed FC connection
SFP speed (S)
SFP speed status
Solid green – 2 Gbit 
Off – 1 Gbit
Table 6-6  Power Supply LEDs 
Purpose LED
LED 
Color 
Definition
Monitors the DC output voltage 
within tolerance specification. 
Overcurrent protection shutting down 
any voltage output is also displayed. 
Voltage thresholds:
+5 VDC +/–.25 VDC
+12 VDC +/–.6 VDC
Current thresholds:
+5 VDC    35A
+12 VDC   25A
Solid green
Solid amber 
Power supply and fans are 
good.
Failed: One or more output 
voltages out of range or one 
or both fans is rotating at less 
than 4000 RPM.