Dot Hill Systems II 200 FC 사용자 설명서

다운로드
페이지 210
B-16
SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005
Figure B-5  JBOD or Expansion Unit Troubleshooting Flowchart, 2 of 2
B.12
Converting a JBOD to a RAID array
You can convert an FC JBOD (or expansion unit) into a single-controller or dual-
controller FC RAID array. For instructions on how to do this, refer to the SANnet II 
Family FRU Installation Guide
.
5B
JBOD or expansion unit problem (FC)
Replace
I/O expansion
module.
Possible midplane
failure.
Replace chassis.
Resolved?
No
No
End
Has a
controller failure
occurred?
Yes
End
Yes
Has a
 data error
occurred?
Correct data error.
Yes
Switch controller with
know good controller.
No
Resolved?
Yes
End
No
Replace chassis.
End
End
--Reseat the FRU that is not operating correctly.
--Swap the questionable FRU with a known-good
FRU from the same array.
Notes
Prior to replacing a chassis, try the following: