SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005
Figure B-5 JBOD or Expansion Unit Troubleshooting Flowchart, 2 of 2
B.12
Converting a JBOD to a RAID array
You can convert an FC JBOD (or expansion unit) into a single-controller or dual-
controller FC RAID array. For instructions on how to do this, refer to the SANnet II
Family FRU Installation Guide.
controller FC RAID array. For instructions on how to do this, refer to the SANnet II
Family FRU Installation Guide.
5B
JBOD or expansion unit problem (FC)
Replace
I/O expansion
module.
Possible midplane
failure.
Replace chassis.
Resolved?
No
No
End
Has a
controller failure
occurred?
Yes
End
Yes
Has a
data error
occurred?
Correct data error.
Yes
Switch controller with
know good controller.
No
Resolved?
Yes
End
No
Replace chassis.
End
End
--Reseat the FRU that is not operating correctly.
--Swap the questionable FRU with a known-good
FRU from the same array.
FRU from the same array.
Notes
Prior to replacing a chassis, try the following:
Prior to replacing a chassis, try the following: