PARTS LIST FOR VENTING KITS 
AND COMpONENTS
DESA (5"/8") Pipe & Vent Kits
Number  Description
P58-6 
6" Section Double Wall Pipe, 
 
Galvanized
P58-12 
12" Section Double Wall Pipe, 
 
Galvanized
P58-24 
24" Section Double Wall Pipe, 
 
Galvanized
P58-36 
36" Section Double Wall Pipe, 
 
Galvanized
P58-48 
48" Section Double Wall Pipe, 
 
Galvanized
PA58-712  Adjustable 7"-12" Section Double 
 
Wall Pipe, Galvanized
E58-45 
45° Elbow, Galvanized
E58-90 
90° Elbow, Galvanized
HTS-58 
Horizontal Square Termination,  
 
Galvanized
VT-58 
Vertical Round Termination,  
 
Galvanized
SC-58 
Storm Collar, Galvanized
WF-58 
Wall Firestop, Galvanized
RF-58-6  Roof Flashing - 0 to 6/12 Pitch,  
 
Galvanized
RF-58-12  Roof Flashing - 6/12 to 12/12 Pitch,  
 
Galvanized
VR-58 
Vertical Restrictor, Galvanized
S-58 
Vinyl Siding Standoff, 
 
Galvanized
WS-58 
Wall Strap
CS-58 
Cathedral Ceiling Support
FP-58 
Firestop Plate
SF-58 
Stucco Flashing - 
 
For use with HTS-58
RF-58 
Flat Roof Flashing
AK6-37 
37" Outside Air Flex Vent Kit
AK6-75 
75" Outside Air Flex Vent Kit
ventinG inStALLAtiOn
Continued
FirePLAce 
inStALLAtiOn
CHECK GAS TYPE
Use proper gas type for the fireplace unit you 
are installing. If you have conflicting gas types, 
do not install fireplace. See retailer where you 
purchased the fireplace for proper fireplace 
according to your gas type.
INSTALLING GAS pIpING TO 
FIREpLACE LOCATION
  WARNING:  A  qualified 
service  person  must  connect 
fireplace to gas supply. Follow 
all local codes.
 CAUTION: For propane/LP 
units,  never  connect  fireplace 
directly to the propane/LP sup-
ply. This heater requires an ex-
ternal regulator (not supplied). 
Install  the  external  regulator 
between the fireplace and pro-
pane/LP supply.
 WARNING: For natural gas, 
never  connect  fireplace  to 
private (non-utility) gas wells. 
This  gas  is  commonly  known 
as wellhead gas.
Installation Items Needed
Before  installing  fireplace,  make  sure  you 
have the items listed below.
•  external regulator (supplied by installer)
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection *
•  sediment trap
•  tee joint
•  pipe wrench
•  approved flexible gas line with gas connec-
tor (if allowed by local codes)
* A  CSA  design-certified  equipment  shutoff 
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase 
the  CSA  design-certified  equipment  shutoff 
valve from your retailer.