Pressing the 
Word Length
 button repeatedly cycles the word length through the
sequence:
24, 23, 22, 21, 20, 19, 18, 17, 16, 24,
  etc.
The Word Length is briefly shown on the main display, and if a setting other than
the maximum is set, the word length LED (above the button) lights.
Noise Shaping is a technique which improves the noise performance of the ADC
in the audio band by moving the quantisation noise energy (introduced by
reducing the word length) from one part of the spectrum to another.  It keeps it
out of the middle of the band, where the ear is most sensitive, and places it at
the top end or ultrasonic region, where the ear is less sensitive or insensitive.
See section 
 on page 64 for more background.
Pressing the 
Noise Shaping
 button repeatedly cycles the unit through 5 noise
Shaping characteristics. The characteristic is shown briefly on the main display.
Auto
Unit sets noise shaping automatically, depending
on word length:
24 bits – no noise shaping
20 to 23 bits – 1
st
 order noise shaping
16 to 19 bits – 3
rd
 order noise shaping
Off
No noise shaping
1st
1
st
 order noise shaping
3rd
3
rd
 order noise shaping
9th
9
th
 order noise shaping
The noise shaping LED (above the button) lights when the setting is other
than 
Auto
.
For Menu operation as the 
Back
 button, see the section 
Overload Level
Menu 
Step
The 
Overload Level
 button is dual function – on its own (
blue
 type on the front
panel) it sets the level at which overloads are detected by the unit. With the
other menu buttons ( 
white
 type on the front panel) it is the menu 
Step
 button.
Overload detection is normally set to full scale. The detection level may be
reduced in 0.1dB steps down to -3dB0 by pressing the 
Overload Level
 button
repeatedly or holding it down. The set level is shown on the display for a few
seconds. The overload level LED (above the button) lights when the setting is
other than full scale (0.0dB0).
For Menu operation as the 
Step
 button, see the section “
Overload Indicator
(Overload LED)
This overload LED lights for a few seconds when the set overload level is
exceeded by a signal peak. The detection circuitry monitors both input and
digital filtering circuitry for overload conditions. The analogue input sensitivity
trims mounted on the rear panel should be set so that the overload indicator
does not light on signal peaks.