Power Consumption
The dCS 904 has a linear power supply, and so power consumption changes as
the mains voltage changes.  The internal regulation is comparatively efficient for
a linear supply, so these changes are kept to a minimum. Power consumption is
independent of mains voltage selector switch setting.
Power Consumption with Mains Voltage (measured as AC power into mains
socket):
Nominal mains
25 W
Mains -10%
22 W
Mains +10%
27 W
The actual intended supply voltage is shown on the rear panel.  50 Hz or 60 Hz
operation is not important – the unit can use either.  In general, users will not
need to change the mains input configuration. If you do need this to be done,
please see the section 
, page
 
manual and contact your distributor or dCS.
Size and Weight
The  dCS 904 dimensions correspond to a standard 2U 19" rack mount case.
Four heavy duty feet, fitted to the base, extend the overall height to slightly
greater than 2U.
Dimensions
Width 
430 mm
see note (i)
Height, without feet
44 mm
(2U)
Height, with feet 
52 mm
Depth
390 mm 
see note (ii)
Weight
6.8   kg
see note (iii)
note (i)
Removable 19" rack mount ears are supplied,
taking total width to 483 mm (19").
note 
(ii)
Measured from front panel to rear panel
connectors. Additional depth should be allowed to
accommodate cable connectors.
note 
(iii)
The high quality case is necessarily heavy,
consideration should be paid to appropriate support