Sample Rate Display
-
The main display generally shows the incoming sample rate, in kS/s, or the
mode (DSD).  When other parameters are set, it briefly shows the new setting
(volume, tone frequency, etc) then reverts to its normal display. In the case of an
error condition, it will display an error message.
If the unit is being slaved to a reference source, the display also indicates which
reference input it is slaved to.
   
xxx
The sample rate, in kS/s (32, 44.1, 48, 88.2, 86,
176.4, or 192).
b xxx
Slaved to the BNC Word Clock In.
r xxx
Slaved to AES Reference In.
d xxx
Temporary display during locking – the unit has
detected the base reference sample rate and is
attempting to lock to it.
. xxx
Temporary display during locking – the unit is lining
up word clock out to word clock in.
Important error messages are given below – a full list is given in the section
BadFs
The clock source is not in pull in range, or is poorly
formatted. The unit cannot lock to it.
Err.xy
An error has been detected. Please refer to
“Internal Device Error Codes”
more specific details on error codes.
Hot
The unit is overheating, probably due to inadequate
ventilation. Please check positioning and cooling.
Ouch
The “
Hot
” warning has been ignored and the unit is
getting so hot that damage may follow.
(blank)
If the display is completely blank for any significant
period, try switching off for 10 seconds then
switching on again. If this does not solve the
problem, contact your distributor or dCS.
The display is also used for Menu options.