The basic installation of this Heat Alarm is the similar whether you want to
install one Heat Alarm, or interconnect more than one Heat Alarm. If you 
are interconnecting more than one Heat Alarm, you MUST read “Special
Requirements for Interconnected Heat Alarms” below before you begin
installation.
ELECTRICAL SHOCK HAZARD. Turn off power to the area where you 
will install this unit at the circuit breaker or fuse box before beginning
installation. Failure to turn off the power before installation may result 
in serious electrical shock, injury or death.
1. Remove the mounting bracket from the base. Position the screw slots
on the mounting bracket over the screws in the junction box. Tighten 
the screws.
2. Using wire nuts, connect the power connector to the household wiring.
Improper wiring of the power connector or the wiring leading to the
power connector will cause damage to the Alarm and may lead to a
non-functioning Alarm.
3. Plug the power connector into the back of the Heat Alarm.
4. Position the base of the Alarm over the mounting bracket and turn. 
Turn the Alarm clockwise (right) until the unit is in place.
5. Check all connections.
ELECTRICAL SHOCK HAZARD. Do not restore power until all Heat
Alarms are completely installed. Restoring power before installation is
complete may result in serious electrical shock, injury or death.
6. Make sure the Heat Alarm is receiving AC power. Under normal 
operation, the green light (LED) will shine continuously.
7. If the green power indicator light does not light, TURN OFF POWER TO
THE JUNCTION BOX and recheck all connections. If all connections are
correct and the power indicator still does not light when you restore the
power, the unit should be replaced immediately.
8. Test each Heat Alarm. Press the Test button until you hear a brief
acknowledge (or feedback) chirp. The alarm will sound: 3 beeps, pause, 
3 beeps, pause. 
When testing a series of interconnected units you must test each
unit individually. Make sure all units alarm when each one is tested.
If any unit in the series does not alarm, TURN OFF POWER and recheck
connections. If it does not alarm during testing when you restore power,
replace it immediately.
SPECIAL REQUIREMENTS FOR INTERCONNECTED HEAT ALARMS
• Failure to meet any of these requirements could damage the units
and cause them to malfunction, removing your protection.
Interconnected units can provide earlier warning of fire than stand-alone
units, especially if a fire starts in a remote area of the dwelling. If any unit 
in the series senses heat, all units will alarm.
Interconnect units within a single family residence only. Otherwise all house-
holds will experience unwanted alarms when you test any unit in the series.
Interconnected units will only work if they are wired to compatible units and 
all requirements are met. This unit is designed to be compatible with 
First Alert
®
and BRK
®
Smoke, CO and Heat Alarms.
Interconnected units must meet ALL of the following requirements:
• A maximum of 18 compatible Smoke, Heat or CO Alarms may be 
interconnected. To comply with NFPA limits, no more than 12 of the 
18 alarms may be Smoke Alarms.
• The same fuse or circuit breaker must power all interconnected units.
• All wiring must conform to all local electrical codes and NFPA 70 (NEC).
Refer to NFPA, Chapter 2 and/or your local building code for further
connection requirements.
FOLLOW THESE INSTALLATION STEPS
STAND-ALONE ALARM ONLY:
Connect the white wire on the power connector to the neutral wire in
the junction box.
Connect the black wire on the power connector to the hot wire in the
junction box.
Tuck the orange wire inside the junction box. It is used for 
interconnect only.
INTERCONNECTED UNITS ONLY:
Strip off about 1/2” (12 mm) of the plastic coating on the orange
wire on the power connector.
Connect the white wire on the power connector to the neutral wire in
the junction box.
Connect the black wire on the power connector to the hot wire in the
junction box.
Connect the orange wire on the power connector to the interconnect
wire in the junction box. Repeat for each unit you are interconnecting.
Never connect the hot or neutral wires in the junction box to the orange
interconnect wire. Damage may result.
Never cross-connect hot and neutral wires between interconnected
Alarms. Damage will result.
STAND-ALONE ALARM ONLY:
If you are only installing one Heat Alarm, restore power to the 
junction box.
INTERCONNECTED UNITS ONLY:
If you are interconnecting multiple Heat Alarms, repeat steps 1-5
for each Heat Alarm in the series. When you are finished, restore
power to the junction box.
6
7
8
4
3
5
4
3
1
5
2
A
B
}
}
1
A. Unswitched 120V AC 
60 Hz source
B. To additional units; Maximum = 18 total
(Maximum 12 Smoke Alarms)
1. Heat Alarm
2. Ceiling or Wall
3. Power Connector
4. Wire Nut
5. Junction Box
6. Neutral Wire (Wht) 
7. Interconnect Wire
(Orange)
8. Hot Wire (Blk) 
3
WEEKLY TESTING
NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home. The built-
in test switch accurately tests the unit’s operation as required by
Underwriters Laboratories, Inc. (UL).
If the Alarm ever fails to test properly, replace it immediately.
Products under warranty may be returned to the manufacturer for
replacement. See “Limited Warranty” at the end of this manual.
DO NOT stand close to the Alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing. When 
testing, step away when horn starts sounding.
It is important to test this unit every week to make sure it is working
properly.
Press and hold the test button until the alarm sends a test command
acknowledge “chirp” just before it sounds continuously (the unit will continue
to alarm for a few seconds after you release the button). If it does not alarm,
make sure it is receiving power and has a fresh battery, and test it again. 
If it still does not alarm, it should be replaced immediately.
When testing one unit, all interconnected alarms will sound. If they don’t,
check the connection with power to the units turned off, restore power and
try again. Test all units in a series, not just one. Using the test button is the
ONLY correct way to test the Heat Alarm.
REGULAR MAINTENANCE
This unit has been designed to be as maintenance-free as possible, but there
are a few simple things you must do to keep it working properly:
Test it at least once a week.
Clean the Heat Alarm at least once a month; gently vacuum the 
outside of the Heat Alarm using your household vacuum’s soft brush
attachment. Test the Heat Alarm. Never use water, cleaners or solvents
since they may damage the unit.
If the Heat Alarm becomes contaminated by excessive dirt, dust and/or
grime, and cannot be cleaned to avoid unwanted alarms, replace the 
unit immediately.
Relocate the unit if it sounds frequent unwanted alarms. See “Locations
to Avoid for Heat Alarms” for details.