 SERVICING INSTRUCTIONS (continued) 
IMPORTANT:  When replacing 
water faucet coil, also replace 
seal gaskets. 
 
 
 
 
 
 
 
 
NOTE:  Any abrasion or     
roughness on the flat end of the 
seat cup will require replacing 
the seat cup: 
 
Work the seat cup out of the    
bonnet and off of the end of the 
stem. 
 
Install a new seat cup, making 
sure the knob on the stem is 
fully inserted into the pocket of 
the seat cup, and the skirt of the 
seat cup is fully inserted into the 
bonnet. 
REPLACE TIMER ASSEMBLY 
 
Unplug power cord or turn circuit breaker OFF. 
 
Remove front panel.  Remove knob and three screws holding 
timer to bracket.  Disconnect wiring to timer. 
 
Reassemble in reverse order. 
Adjust timer as described on page 13 
 
REPLACE HOT WATER FAUCET COIL 
 
Symptom:  Brewer drips continuously from brew head, except 
when faucet valve is turned OFF. 
 
Remove tank lid assembly per above. 
 
Remove two hex nuts hot water coil to cover.  Pull coil from 
mounting holes. 
 
Reassemble in reverse order. 
 
REPAIR HOT WATER FAUCET 
 
Remove top panel and turn faucet valve OFF. 
 
Unscrew aerator cap from faucet and remove handle retaining 
clip.  Do not let faucet body turn. 
 
Pull bonnet assembly from faucet body. 
 
Examine the interior of the faucet body and the surface of the 
seat cup.  Clean out any debris in the faucet body, using a stiff 
bristle brush if necessary.   
 
Examine the aerator.  Clean any debris from the screen or flow  
straightener, using a stiff bristle brush if necessary. 
 
Reassemble in reverse order. 
 
REPLACE BREW READY LIGHT or BREW BUTTON 
 
Unplug power cord or turn circuit breaker OFF. 
 
Using Switch Removal Tool (p/n 83209) or a thin screwdriver, pry 
light or switch from mounting hole.  Disconnect leads. 
 