BIPAC-2AB 2.0 User’s Manual 
Programming the BIPAC-2AB 2.0 Functions 
The functions of BIPAC-2AB 2.0 are programmed by the use of the telephone 
number keys (0 ~ 9), the pound key (#), and the star key (*). 
 
You should hear 2 short tones if the programming is 
successful; otherwise, you will hear more than 6 tones 
indicating failure of programming. 
 
Function 
Name 
ID  k 
First 
Field 
Second
Field 
k
e
y
Third 
Field 
k
e
y
Note 
Password 
Setup 
* 98 *  Old 
Pass 
* New 
Pass #
 
 
Password 
Enabling 
* 97 *  Pass  * 
Flag  #
 
Flag=0: 
disable 
password 
Flag=1: enable password 
Factory 
Default 
*  96  * 
Pass  * 
Id 
#
 
Id=0 or null: default setting 
Special 
function 
Setup 
* 95 *  Pass  *  Func 
Id
*
Flag 
# Func 
Id=1, 
PCM 
Law 
 Flag=0 or null: A-Law 
 Flag=1: µ Law 
Func Id=2, Bearer capability 
 Flag=0 or null: 3.1kHz audio 
 Flag=1: speech 
 Flag=2: G3 Fax 
Func Id=3, Ring Signal 
Flag=0 or null: 25Hz 
Flag=1: 16Hz 
Flag=2: 50 Hz 
Func Id=4, Not check in-band tone 
 Flag=0 or null: disable 
 Flag=1: enable