Behringer Tube Ultragain MIC200 사용자 설명서
19
TUBE ULTRAGAIN MIC200 User Manual
TUBE ULTRAGAIN MIC200 User Manual
System Data
Signal-to-noise ratio
90 dB A-weighted @ -28 dBu input level
Frequency Response
Mic input
<10 Hz to 47 kHz (±3 dB)
Line input
<10 Hz to 55 kHz (±3 dB)
Function Controls
GAIN
variable (+26 dB to +60 dB)
OUTPUT
variable (-∞ to +10 dB)
Preamp mode control
selection of various preamp settings for microphone
and instruments
Function Switches
20 dB PAD
level attenuation (20 dB)
+48 V
activates the phantom power
LOW CUT
High pass filter (cut-off frequency 90 Hz)
PHASE REVERSE
Phase reverse (180°)
Indicators
Input Level
8-segment LED meter:
-24, -18, -12, -6, 0, +6, +12, Clip
Power LED
indicates operation