11. ELECTRICAL MECHANISM 
 
Z-8550A, 8560A
 
97
11-5-3. Remedy 
If a problem No. is reached while carrying out the diagnosis steps in “11-5-2. Diagnosis flowchart”, refer to the table for the 
corresponding number.After identifying the cause in the “Cause” column, carry out the steps in the 
“Inspection/Remedy/Adjustment” column, and if a malfunction is found, replace the parts specified in “Replacement if a 
malfunction”. 
 
Problem No. 1 
The power indicator (red) on the power supply P.C. board does not illuminate when the power 
switch is turned on. 
 
Cause Inspection/Remedy/Adjustment 
Replacement if a malfunction 
1.  If the red LED on the power supply 
P.C. board is not illuminated: 
Malfunction of power supply P.C. 
board or transformer 
Check the power cord. 
•  Is fuse F1 or F2 on the power supply P.C. 
board blown? 
•  Is the primary coil of the transformer burnt 
out? 
If fuse F1 or F2 is blown, 
replace the power supply P.C. 
board or transformer. 
1)  Check if the secondary coil of the 
transformer is burnt out or if there is an 
open circuit. 
Transformer 
If the power indicator (green) on the main P.C. 
board is not illuminated: 
2)  Check if fuse resistor R25 on the main P.C. 
board is blown.
 
Main P.C. board 
2.  If the red LED on the power supply 
P.C. board is illuminated: 
Malfunction of transformer, main 
P.C. board or panel assembly 
If the power indicator (green) on the main P.C. 
board is illuminated: 
3)  (Replace the part(s) indicated at right.)
 
Main P.C. board or panel 
assembly 
 
 
Problem No. 2 
An error code is displayed when the power switch is turned on. 
 
Cause Inspection/Remedy/Adjustment 
Replacement if a malfunction 
1)  Check if thread scraps are blocking the 
cooling fans (for oil pan and control box). 
1.  When [Err 740] is displayed: 
The cooling fan for the oil pan is 
disconnected or not operating, or 
the cooling fan inside the control 
box is not operating. 
2)  Check that connector P23 (FAN1) and 
connector P32 (FAN2) are inserted into the 
main P.C. board. 
DC fan motor assembly 
2.  When [Err 65] is displayed: 
One of the keys on the operation 
panel is still depressed. 
Check that connector P21 (PANEL) is inserted 
into the main P.C. board. 
Panel assembly 
 
3.  When [Err 95] is displayed: 
Power switch was turned on while 
treadle was depressed. 
Return the treadle to the neutral position and 
turn the power switch off and back on again to 
check. 
Treadle unit 
4.  When [Err 90] is displayed: 
Poor connection for treadle unit 
connector 
Check that connector P11 (PEDAL) is inserted 
into the main P.C. board. 
Treadle unit