Bradley Smoker HN200 사용자 설명서
ADA Compliant Recess-Mounted Shower
Installation Instructions
HN200
Bradley Corporation • 215-1189 Rev. F; EN 02-342
5
Installation Instructions continued…
Step 2: Make plumbing connections
NOTE: Hoses need to be connected to 1/2" NPT pipe supply
before the shower is fastened to the wall.
before the shower is fastened to the wall.
1. Make water supply connections to the stainless steel hoses
(see Figure 2). Equa-Flo™ and Thermostatic= 1/2" NPT
Hot and Cold supplies. Single Valve, Accu-Zone™ Infrared
Control, Air Valve and Touch Time™ = 1/2" tempered
supply.
Hot and Cold supplies. Single Valve, Accu-Zone™ Infrared
Control, Air Valve and Touch Time™ = 1/2" tempered
supply.
Step 3: Install face plate and grab bar
1. Position the face plate on the wall. Mark the wall and install
twelve wall anchors suitable for use with 1/4"-20 x 3/4"
button head Allen key screws (see Figure 3).
button head Allen key screws (see Figure 3).
2. Attach the face plate to the wall with twelve 1/4"-20 x 3/4"
button head Allen key screws provided (see Figure 3).
3. Attach the grab bar to the wall.
• Position the “L” of the grab bar to fit the back wall of the
shower stall.
4. Use the flange as a template and mark the six screw hole
locations and install six anchors supplied by installer for
1/4"-20 x 1-1/4" flat head Allen key
screws (see Figure 3).
1/4"-20 x 1-1/4" flat head Allen key
screws (see Figure 3).
5. Secure the grab bar to the six wall
anchors using six 1/4”-20 x 1-1/4"
flat head Allen key screws (provided
by installer) (see Figure 3).
flat head Allen key screws (provided
by installer) (see Figure 3).
Figure 3
NOTE: ALL WALL
ANCHORS SUPPLIED
BY INSTALLER.
ANCHORS SUPPLIED
BY INSTALLER.
GRAB BAR
(S53-184)
(S53-184)
1/4"-20 x 3/4"
BUTTON HEAD
ALLEN KEY SCREW
(12) PLACES
(160-143)
BUTTON HEAD
ALLEN KEY SCREW
(12) PLACES
(160-143)
1/4"-20 x 1-1/4"
FLAT HEAD ALLEN
KEY SCREW
FLAT HEAD ALLEN
KEY SCREW
FACE PLATE
VALVE LEFT - SEAT RIGHT
Figure 2
VALVE LEFT
SEAT RIGHT
SEAT RIGHT