Boss Audio Systems GT-100 사용자 설명서

다운로드
페이지 38
CTL/EXP
32
ASSIGN COMMON
Parameter
Value
Explanation
INPUT SENS
0–100
This adjusts the input sensitivity when INPUT 
LEVEL is selected for SOURCE .
ASSIGN 1–8
*  If you want to light the ACCEL/CTL pedal’s LED indicator while the 
ASSIGN 1–8 function is assigned to the ACCEL/CTL pedal, set the ACCEL/
CTL pedal FUNC (p . 31) to “LED ON/OFF .”
Parameter
Value
Explanation
OFF/ON
OFF, ON
Turns the ASSIGN 1–8 on/off .
SOURCE
EXP PEDAL
Assigns the GT-100’s [EXP] pedal .
EXP PDL SW
Assigns the EXP pedal switch .
P .LOOP PEDAL
Assigns the GT-100’s [PHRASE LOOP] pedal .
ACC/CTL PDL
Assigns the [ACCEL/CTL] pedal .
SUB EXP PDL
Assigns the external expression pedal (such as 
the separately available EV-5) connected to the 
SUB CTL 1, 2/SUB EXP jack .
SUB CTL1 PDL
Assigns the external footswitch (FS-5U, FS-6; 
available separately) connected to the SUB CTL 
1, 2/SUB EXP jack .
SUB CTL2 PDL
Assigns the external foot switch (FS-5U, FS-6; 
available separately) connected to the SUB CTL 
1, 2/SUB EXP jack .
INT PEDAL
WAVE PEDAL
INPUT LEVEL
The assigned target parameter will change 
according to the input level .
CC#1–#31
Control Change messages from an external MIDI 
device .
CC#64–#95
Control Change messages from an external MIDI 
device .
SOURCE MODE
MOMENT
The normal state is Off (minimum value), with 
the switch On (maximum value) only while the 
footswitch is depressed .
TOGGLE
The setting is toggled On (maximum value) 
or Off (minimum value) with each press of the 
footswitch .
TARGET 
CATEGRY
This selects the parameter to be changed .
Refer to TARGET list
TARGET
TARGET MIN
This sets the minimum value for the range in which the parameter 
can change . The value differs depending on the parameter 
assigned for TARGET parameter .
TARGET MAX
This sets the maximum value for the range in which the parameter 
can change . The value differs depending on the parameter 
assigned for TARGET parameter .
ACT RANGE LO 0–126
You can set the controllable range for target 
parameters within the source’s operational 
range . Target parameters are controlled within 
the range set with ACT RANGE LO and ACT 
RANGE HI . You should normally set ACT RANGE 
LO to 0 and ACT RANGE HI to 127 .
ACT RANGE HI 1–127
WAVE RATE *1
0–100,  
BPM  –
This determines the time spend for one cycle of 
the assumed EXP Pedal .
When set to BPM, the value of each parameter will be set accord-
ing to the value of the “MASTER BPM” specified for each patch . This 
makes it easier to achieve effect sound settings that match the 
tempo of the song .
*  If, due to the tempo, the time is longer than the range of 
allowable settings, it is then synchronized to a period either 1/2 
or 1/4 of that time .
Parameter
Value
Explanation
WAVEFORM *1
SAW
TRI
SINE
INT PDL 
TRIGGER *2
PATCH CHANGE This is activated when a patch is selected .
EXP PDL-LO
This is activated when the GT-100’s [EXP] pedal is 
set to the minimum position .
EXP PDL-MID
This is activated when the GT-100’s [EXP] pedal is 
moved through the middle position .
EXP PDL-HI
This is activated when the GT-100’s [EXP] pedal is 
set to the maximum position .
EXP PDL SW
This is activated when the EXP pedal switch is 
operated .
P .LOOP PEDAL
This is activated when the [PHRASE LOOP] pedal 
is operated .
ACC/CTL PDL
This is activated when the [ACCEL/CTL] Pedal is 
operated .
SUB EXP PDL
This is activated when an external expression 
pedal connected to the SUB CTL 1, 2/SUB EXP 
jack is operated .
SUB CTL1 PDL
This is activated when an external footswitch 
connected to the SUB CTL 1, 2/SUB EXP jack is 
operated .
SUB CTL2 PDL
This is activated when an external footswitch 
connected to the SUB CTL 1, 2/SUB EXP jack is 
operated .
CC#1–#31
This is activated when a control change is 
received .
CC#64–#95
This is activated when a control change is 
received .
INT PDL TIME 
*2
0–100
This specifies the time over which the internal 
pedal will move from the toe-raised position to 
the toe-down position .
INT PDL 
CURVE *2
LINEAR
SLOW RISE
FAST RISE
*1 The WAVE RATE and WAVEFORM parameters are enabled when the Source 
parameter is set to WAVE PEDAL .
*2 The INT PDL TRIGGER, INT PDL TIME, and INT PDL CURVE parameters are enabled 
when the SOURCE parameter is set to INT PEDAL .