Bosch AG Computer Accessories R911310079 사용자 설명서

다운로드
페이지 86
4-2
 Technical Data
VSB 40.1
DOK-SUPPL*-VSB*40.1***-PR02-EN-P
4.2 
Power Supply 115 V / 230 V
Nominal input voltage:
115 VAC / 230 VAC
Input voltage range:
90 ... 264 VAC
Input current:
2.5 A for nominal voltage 230 VAC
5.0 A for nominal voltage 115 VAC
Inrush current:
100 A for 264 VAC
Current
Output voltages:
+3.3 V
+5 V
+12 V
12 V
+5 V SB
Min.
0,5 A
0,5 A
1,0 A
0 A
0 A
Max.
20 A
25 A
17 A
0.8 A
2.0 A
Tolerances
+/-  5 %
+/-  5 %
+/-  5 %
+/-10 %
+/-  5 %
Max. Output power:
250 W*
Efficiency (under full load):
0.73 for 115 VAC, 0.76 for 230 VAC
*) Note: During specifying the maximum output currents please observe that the currents
separately considered are the maximum possible currents of the respective output voltage.
However, it is not possible to create the maximum current from all output voltages, as the
maximum total output power (= 250 W) must not be exceeded.
In addition, the maximum power at +3.3 V together with +5 V must not exceed 150 W or
33 A.
Fig. 4-2:
Technical data of the power supply unit 115 V / 230 V
4.3 
Power Supply Unit 24 V
Nominal input voltage:
24 VDC
Input voltage range:
19 ... 32 VDC
Input current:
20 A for 19 VDC
Inrush current:
5 A
Current
Output voltages:
+3.3 V
+5 V
+12 V
12 V
5 V
+5 V SB
Min.
0 A
2 A
0.1 A
0 A
0 A
0 A
Max.
15 A
30 A
15 A
2.0 A
2.0 A
1.2 A
Tolerances
+2.93 V ... +3.40 V
+4.80 V ... +5.20 V
+11.4 V ... +12.6 V
 11.4 V ... -12.6 V
 4.75 V ... -5.25 V
+4.75 V ... +5.25 V
Max. output power:
300 W*
Efficiency (under full load):
> 0,65
*) Note: During specifying the maximum output currents please observe that the currents
separately considered are the maximum possible currents of the respective output voltage.
However, it is not possible to create the maximum current from all output voltages, as the
maximum total output power (= 300 W) must not be exceeded.
In addition, the maximum power at +3.3 V together with +5 V must not exceed 150 W.
Fig. 4-3:
Technical data of the power supply unit 24 V