Bosch Appliances Video Game Controller D9412GV2 사용자 설명서

다운로드
페이지 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 59 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
• 
• 
For example: The Change Display (COMMAND 
49) function has three sub-functions: Bright 
Display, Dim Display, and Date/Time Display. 
Programming Custom Function Keystrokes 
 
•  Find the command you want to execute in the 
User Interface section of the program record 
sheet. Single digit commands must be 
programmed with 9 as the second digit. 
To turn up the display, enter: 
[A][4][9][E] 
To dim the display, enter: 
[A][4][9][D][E] 
Table 26: CF### Custom Function Keystrokes 
 
To display time and date, enter:   
[A][4][9][B][E] 
Command Keystroke 
1 (Master arm area) 
A19 
 
Custom Functions can perform several tasks at 
one time. For example: 
2 (Perimeter instant arm) 
A29 
3 (Perimeter delay arm) 
A39 
−  To toggle relays 7, 8, and 9 in one Custom 
Function enter:   
[A] [5] [4] [7] [E] [E] [8] [E] [E] [9] [E] [E] [C] 
6 (Watch Mode) 
A69 
7 (Special alert) 
A79 
8 (Perimeter partial  arm) 
A89 
9 ( Special alert) 
A99 
−  To add a temporary pass code, enter: 
[A] [5] [6] [3] [0] [E] [E] [9] [8] [7] [E] [E] [D] [E] 
[1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] [1] [E] 
[1] [E] [C] 
This adds user 30, pass code 987 with 
authority level 1 in all areas. 
0 (Bypass a point) 
A09 
 
• 
• 
When CF### Custom Function is programmed 
with P, the corresponding custom function 
number is passcode protected. The CF### 
Custom Function
 prompt is under GV2MAIN > 
User Interface > Cmd Center Functions. The 
passcode protected custom function can be 
added to a keypad’s function list by programming 
its number in the GV2MAIN > Function List >  M# 
Function prompt. 
−  To delete the pass code, enter: 
[A] [5] [3] [3] [0] [E] [E] [E] [C] 
To program multiple-area Arming or Disarming 
functions, use keystroke sequences including 
COMMAND 50 (Move to Area) and 
COMMAND 1. 
128 to 143 Enable Custom Function 128 
through 143, (Menu Function only):
 This 
function determines if a pass code is needed to 
access a Custom Function from the menu list. 
ENTER PASSCODE (or Enter Passcode + Enter 
Key on the D1260) appears when this function is 
pass-code protected. 
 
Custom function cannot be used to 
change time (such as Daylight Saving 
Time). Use Skeds S## Function Codes 
 
13 and 14 to adjust for Daylight Saving 
Time (refer to S## Custom Function 
prompt in Section 5.2 Skeds on page 
115. 
 
 
If a command within the Custom Function 
Example 1 
is pass-code protected, ENTER 
Execute the third function in a keypad menu function 
list: 
PASSCODE appears at the keypad. The 
 
user must enter a valid pass code before 
proceeding with the rest of the Custom 
Function. If a pass code is not entered 
within 10 sec, the Custom Function times 
out and the display returns to idle text. 
D1255 CDDE 
D1260 C8C7C5 
The custom functions in Example 1 are 
 
 
not compatible between keypad types. 
Skeds cannot execute Custom Functions 
 
that are pass-code protected. The D720 
LED keypad does not support Custom 
Example 2 
 
Functions that are pass-code protected. 
Instant master Arm (CMD 11): 
Some functions cannot be entered directly 
because they are nested inside a higher-level 
function. To automatically execute these 
functions, you must add the appropriate 
keystrokes. 
D1255 A11 
D1260 A11 
The custom functions in Example 2 are 
compatible between keypad types.