Bay Technical Associates BayTech DS72 사용자 설명서

다운로드
페이지 35
DS72 HOST MODULE OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
12
Module  1 Serial Port Configuration :
Port
Device
Name
Baud
Rate
Word
Size
Stop
Bits
Parity
Xon/
Xmit
Xoff/
Recv
Line
DTR
Drive
RTS
1
EIA-232
115.2K
8
1
None
Off
Off
High
High
Save.......1  Parity............5
Baud Rate..2  Xon/Xoff..........6
Word Size..3  RTS Line Driver...7
Stop bits..4  DTR Line Driver...8
Enter Request :
Set Word Size by selecting #3, “Set Word Size.”  The DS72 displays the
following list of available word sizes:
1  For  5
2  For  6
3  For  7
4  For  8
Enter the corresponding number for the desired word size.  The DS72
responds with the new configuration status:
Module  1 Serial Port Configuration :
Port
Device
Name
Baud
Rate
Word
Size
Stop
Bits
Parity
Xon/
Xmit
Xoff/
Recv
Line
DTR
Drive
RTS
1
EIA-232
9600
7
1
None
Off
Off
High
High
Save.......1  Parity............5
Baud Rate..2  Xon/Xoff..........6
Word Size..3  RTS Line Driver...7
Stop bits..4  DTR Line Driver...8
Enter Request :
To permanently save configuration changes, select 1, “Save,” from the
selection menu, followed by  <cr>. The DS72 responds:
Change Host Device to Match NEW Configuration
Before Answering this Request
Save Changes Permanently ? (Y/N) :
IMPORTANT:  This message reminds you to change the serial port configuration of the host
terminal to match the new configuration changes made to the serial port on the host module before
answering the question.  If they do not match, the DS72 will be unable to interpret the next
command, and you will be unable to access any connected unit.  If this happens, recycle power and
reconfigure the unit.  Make any necessary changes to the host device before answering "Save
Changes Permanently?"
If you have made necessary changes to the host device, type "Y" for yes,
followed by <cr>.  New configuration changes are stored permanently in
non-volatile memory.
PORT DEVICE NAME
Port Device Name is a user programmable feature that uniquely identifies
the port (or device connected to the port) you are configuring.  The default
name is EIA-232.