Whirlpool ACE082XP1 사용자 설명서

다운로드
페이지 28
5
Recommended ground method
For your personal safety, this air conditioner must be grounded. 
This air conditioner is equipped with a power supply cord having 
a grounded 3 prong plug. To minimize possible shock hazard, the 
cord must be plugged into a mating, grounded 3 prong outlet, 
grounded in accordance with all local codes and ordinances. If a 
mating outlet is not available, it is the customer's responsibility to 
have a properly grounded 3 prong outlet installed by a qualified 
electrical installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 - 
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
INSTALLATION INSTRUCTIONS
Unpacking
Remove packaging materials
Remove and properly dispose of packaging materials.  
Remove tape and glue residue from surfaces before turning 
on the air conditioner. Rub a small amount of liquid dish soap 
over the adhesive with your fingers. Wipe with warm water 
and dry.
Do not use sharp instruments, rubbing alcohol, flammable 
fluids, or abrasive cleaners to remove tape or glue. These 
products can damage the surface of your air conditioner. 
Handle air conditioner with care.  
1. Remove air conditioner from carton and place on cardboard.
2. Remove shipping screw from side wall of cabinet.
3. Pull control knobs off (on some models).
4. Remove front panel from air conditioner and set aside.
5. Remove ground screw and ground wire from front of air 
conditioner base. Save ground screw.
 
6. Pull on handle to slide air conditioner out of cabinet. Place air 
conditioner on cardboard.
NOTE: Do not lift, push, pull or remove any expanded 
polystyrene (foam) from inside the air conditioner. It is not 
packing material.
230 volt (207 min. - 253 max.)
230/208 volt (197.6 min. - 
253 max.)
0-12 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
230 volt (207 min. - 253 max.)
230/208 volt (197.6 min. - 
253 max.)
0-16 amps
20-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
¹⁄₄
"
(0.6 cm)
A. Shipping screw
Excessive Weight Hazard
Use two or more people to move and install 
air conditioner.
WARNING
Failure to do so can result in back or other injury.
A
A. Green ground wire
B. Ground screw
A. Handle
A
B
+
+
+
A