TROUBLE-SHOOTING GUIDE 
PROBLEM 
PROBABLE CAUSE 
CORRECTIVE ACTION 
No power. 
Battery cables corroded 
at battery terminals. 
Faulty main switch. 
Faulty safety override 
switch. 
1. 
Clean battery cable clamps and battery terminals. 
2. 
Check voltage at points 
and B.  Voltage should be 
22/26 
VDC. 
1. 
Check voltage at points 
and C.  Voltage should be 
22/26 
VDC. 
2. 
Turn main switch on and check voltage at points B and D.  Voltage should be 
With main switch 
“ON” 
check voltage at points B and 
G,  and B and 
H. 
If no voltage 
at B and 
remove leads and check micro-switch for continuity.  Should have con- 
tinuity in normal position and no continuity when switch is activated. 
22/26 
VDC. 
If 
no voltage remove leads and check switch for continuity. 
Vacuum motor 
does not run. 
Brush motor 
does not run. 
Solution 
does not work. 
Battery charge 
lndlcator 
does not light. 
14 
Circuit breaker tripped. 
Loose connection. 
Faulty 
switch. 
Faulty 
relay. 
Faulty 
circuit 
breaker. 
Motor brushes worn. 
Circuit breaker tripped. 
Loose connections. 
Faulty brush switch. 
Faulty brush relay. 
Faulty brush circuit 
breaker. 
Motor brushes worn. 
Loose connections. 
Faulty solution light. 
Light stays on with 
solution lever in 
“OFF”  position. 
Loose connections. 
Faulty PC Board or 
faulty  light. 
Reset 
motor circuit breaker 
(20 
amp). 
Check motor lead connections at terminals. 
Remove leads and check switch for continuity. Replace as needed. 
main  switch  “ON”  and 
switch 
“ON” 
check  voltage  at  points  B and  I. 
Voltage should be 
22/26 
VDC. 
With  main switch  “ON”  and 
switch  “ON”  check  voltage at  points B and J. 
Voltage should be 
22/26 
VDC. 
Check motor brushes. 
when worn 
to 
With batteries 
charaed 
and motor secured 
apply ’battery voltage directly to motor. 
No 
load amp draw of 
motor should be 
6.2 
amps. 
Reset circuit breaker. 
Check motor leads at terminal block connections (located on inside front  of frame). 
Tighten screws as needed. 
Remove leads and check switch for continuity. Replace as needed. 
With main switch “ON”  and brush switch “ON”  check voltage at points B and 
K. 
Voltage should be 
22/26 
VDC. 
With main switch “ON”  and brush switch “ON”  check voltage at points B and L. 
Voltage should be 
22/26 
VDC. 
Check motor  brushes.  Replace when  worn  to 
With  batteries fully  charged 
and motor secured, apply  battery voltage directly 
to 
motor.  No load amp draw of 
motor should be 
to 
amps. 
Check for  loose connections at solution light, solution switch and at 
fan  relay 
ground. 
Remove light and apply direct voltage 
(24 
VDC) 
to light. Replace light as needed. 
Adjust solution light switch. 
Check  connections  at  battery  card,  micro-switch  at  charger  Connection,  and 
ground connection at 
motor relay. 
Check voltage into PC Board (point T). Voltage should be 
22/26 
VDC.  Check voltage 
across first  pin (from right) and eighth pin (from right) point U.  Voltage should be 
8/10 VDC.  If voltage  is 
8/10 
VDC  replace  battery  charge  level  indicator  light.  If 
there is no voltage replace PC Board.