MAINTENANCE-VACUUM MOTOR 
86302100 CLIPPER DUO 10/02/07 
4-7 
  
ONLY QUALIFIED 
MAINTENANCE 
PERSONNEL ARE TO PERFORM THE 
FOLLOWING REPAIRSVACUUM MOTOR 
REPLACEMENT
 
1. 
Turn off all switches and unplug machine. 
2. 
Remove recovery tank. 
3. 
Remove the (2) screws that fasten the solution 
tank to the frame, and tilt tank back to expose 
the inside of the frame. 
4. 
Locate the vacuum motor wires and disconnect 
at the connector. Close the solution tank. 
5. 
Remove the (6) screws holding the vacuum 
motor cover to the solution tank. 
6. 
Remove the vacuum motor. 
7. 
Reverse process to install vacuum motor. 
 
 
 
 
 
 
Vacuum Motor Carbon Brushes Replacement 
WARNING: The green 
ground wire must be 
attached for safe operation. 
See wiring diagram. 
End Cap 
Carbon  
Brushes  
If armature commutator is grooved, extremely pitted or not 
concentric, the motor will need to be replaced or sent to a 
qualified service center. 
Important: 
These brushes wear quicker as the length shortens due to 
increased heat. Spring inside brush housing will damage 
motor if brushes are allowed to wear away completely. 
Periodically check the length of the carbon brushes. Replace 
both carbon brushes when either is less than 3/8" (9.5mm) 
long. 