Wilton PF3-EZ 사용자 설명서

다운로드
페이지 28
 
12
Extension Cords 
If an extension cord is necessary make sure the 
cord rating is suitable for the amperage listed on 
the machine's motor plate. An undersize cord 
will cause a drop in line voltage resulting in loss 
of power and overheating. 
The chart in Figure 7 shows the correct size 
cord to use based on cord length and motor 
plate amp rating. If in doubt, use the next 
heavier gauge. The smaller the gauge number 
the heavier the cord. 
 
Adjustments 
Swing 
To swing the Stock Feeder laterally, loosen the 
cam handle counterclockwise so that it pushes 
down the pin, as shown in Figure 8. Swing the 
horizontal arm and feeder into desired position 
(the top part of the stand will rotate). When the 
Stock Feeder is properly positioned, tighten cam 
handle. 
To rotate the top of the stand back to original 
position, loosen the cam handle and rotate the 
top section of the stand, allowing the pin to snap 
back into the hole. Tighten the cam handle. 
 
Raise/Lower 
To raise or lower the Stock Feeder, loosen the 
handle (A, Figure 9) and rotate the elevating 
handle (B, Figure 9). When finished, tighten the 
handle (A, Figure 9). 
 
Forward/Back 
To move the horizontal arm forward or back, 
loosen the handle (C, Figure 9) and rotate the 
handwheel (D, Figure 9).  When finished, tighten 
the handle (C, Figure 9). 
 
Rotate 
To rotate the Stock Feeder (up to 360 degrees), 
loosen the handle on the vertical arm (A, Figure 
9). When finished rotating the Stock Feeder, 
tighten the handle (A, Figure 9). 
 
Recommended Gauges (AWG) of Extension Cords 
Extension Cord Length *  
Amps 
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
5  16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 to 20 
10 
10 
10 
NR 
NR 
NR 
21 
to 
30  10  NR NR NR NR NR 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended.
 
Figure 7 
 
Figure 8 
 
Figure 9