White Rodgers 668-401 Kwik-Sensor CAD Cell Relays 카탈로그

다운로드
페이지 1
OIL BURNER
CONTROLS
Indicates Canadian Model Number: call 1-800-305-6953 to order
668 SERIES KWIK-SENSOR CAD CELL RELAYS
Replaces Intermittent Ignition Kwik-Sensor CAD Cell Relays on Oil
Burner Systems with 30 or 45 Second Safety Timing. Certain Types 
have Unique Signal-Lite Feature which Glows Whenever Safety Lock-
Out Occurs
FEATURES
• Grey metal enclosure.
• Line voltage safety switch eliminates burner run-on in event motor relay contacts
  weld closed.
• Solid state flame detection circuitry is not affected by vibration or high or low
  ambient temperatures. Suitable for use from – 40 to 150°F (– 40 to 66°C)
• Recycles upon momentary flame failure or power interruption.
SPECIFICATIONS
Input Voltage. . . . . . . . . . . . . . . . . . . . . . .   120 VAC, 60 Hz
Control Voltage. . . . . . . . . . . . . . . . . . . . .   24 VAC
Motor Relay Contacts Rating . . . . . . . . . .   Full 10 FLA, 60 LRA, 120 VAC
Ignition Transformer Rating  . . . . . . . . . . .   360 VA (3.0A)
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . .   10” useable leads, mounts to
   
  4 x 4” junction box
668-401
668-451
FLAME DETECTORS
Solid State Electronic Flame Detector which Utilizes Light Intensity to
Sense the Presence of a Flame in Oil Burning Heating Equipment
 
Model 
 
 
Number 
Description
 
956-1
Standard flame detector with straight bracket. 48½” leads.
 
956-154
Universal flame detector with 6 brackets. 60” leads.
 
956-154
 
Model 
 
 
Thermostat 
Safety 
Manual 
Integral 
Time Start
  Number 
Safety Timing 
Thermostat Type 
Anticipator Setting 
Lock-Out Lamp 
Lock-Out Lever 
Transformer 
Fan Switch
 
668-401 
45 seconds 
2-Wire 
0.4A 
No 
No 
No 
No
 
668-451 ➀ 
45 seconds 
2-Wire 
0.4A 
No 
No 
40VA 
C-W
 
668-515 
30 seconds 
2 or 3-Wire 
0.4A 
Yes 
Yes 
No 
No
 Models with external transformer have safety switch contacts in motor relay (low voltage) circuit.
HEA
TING
www.white-rodgers.com
73