White Rodgers 668-401 Kwik-Sensor CAD Cell Relays 카탈로그
OIL BURNER
CONTROLS
Indicates Canadian Model Number: call 1-800-305-6953 to order
668 SERIES KWIK-SENSOR CAD CELL RELAYS
Replaces Intermittent Ignition Kwik-Sensor CAD Cell Relays on Oil
Burner Systems with 30 or 45 Second Safety Timing. Certain Types
have Unique Signal-Lite Feature which Glows Whenever Safety Lock-
Out Occurs
FEATURES
• Grey metal enclosure.
• Line voltage safety switch eliminates burner run-on in event motor relay contacts
weld closed.
• Solid state flame detection circuitry is not affected by vibration or high or low
ambient temperatures. Suitable for use from – 40 to 150°F (– 40 to 66°C)
• Recycles upon momentary flame failure or power interruption.
SPECIFICATIONS
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . 120 VAC, 60 Hz
Control Voltage. . . . . . . . . . . . . . . . . . . . . 24 VAC
Motor Relay Contacts Rating . . . . . . . . . . Full 10 FLA, 60 LRA, 120 VAC
Ignition Transformer Rating . . . . . . . . . . . 360 VA (3.0A)
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . 10” useable leads, mounts to
4 x 4” junction box
668-401
668-451
FLAME DETECTORS
Solid State Electronic Flame Detector which Utilizes Light Intensity to
Sense the Presence of a Flame in Oil Burning Heating Equipment
Model
Number
Description
956-1
Standard flame detector with straight bracket. 48½” leads.
956-154
Universal flame detector with 6 brackets. 60” leads.
956-154
Model
Thermostat
Safety
Manual
Integral
Time Start
Number
Safety Timing
Thermostat Type
Anticipator Setting
Lock-Out Lamp
Lock-Out Lever
Transformer
Fan Switch
668-401
45 seconds
2-Wire
0.4A
No
No
No
No
668-451 ➀
45 seconds
2-Wire
0.4A
No
No
40VA
C-W
668-515
30 seconds
2 or 3-Wire
0.4A
Yes
Yes
No
No
➀
Models with external transformer have safety switch contacts in motor relay (low voltage) circuit.
HEA
TING
www.white-rodgers.com
73