Application of this type of control may cause 
flame rollout on initial startup and could cause 
personal injury and/or property damage.
Check product specification and cross reference 
before replacing existing module. Do not use if 
existing module is not listed. Use of a program 
key other than listed can result in appliance 
malfunction.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY 
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE 
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
CONTENTS
Description  ...................................................................  1
Precautions  ..................................................................  1
Specifications  ...............................................................  2
Installation  ....................................................................  2
Mounting & Wiring .........................................................  2
Operation & Troubleshooting  ........................................  4
DESCRIPTION 
PRECAUTIONS 
GENERAL PRECAUTION
!
To prevent electrical shock and/or equipment 
damage, disconnect electric power to system at 
main fuse or circuit breaker box until installation 
is complete.
Label all wires prior to disconnection when 
servicing controls. Wiring errors can cause 
improper and dangerous operation.
This control is not intended for use in locations 
where it may come in contact with water. Suitable 
protection must be provided to shield the control 
from exposure to water (dripping, spraying, rain, 
etc.).
CAUTION
!
The 50D50-842 is a universal replacement Direct Spark 
control designed for maximum compatibility with existing 
systems. It features:
A card port and eight program keys to select the 
Trial for Ignition Time, Retries, Pre-purge and 
Recycle timings
.
A  Jumper  to  accommodate  systems  using  Direct 
Sense (sensing through ignitor) or Indirect Sense 
(using a Flame Sensor)
LED indicator for quick system and module diagnostics
and troubleshooting.
Do not use on circuits exceeding specified voltage. 
Higher voltage will damage control and could 
cause shock or fire hazard.
Do not short out terminals on gas valve or primary 
control to test. Short or incorrect wiring will 
damage thermostat and could cause personal 
injury and/or property damage.
WARNING
!
If in doubt about whether your wiring is millivolt, line, or 
low voltage, have it inspected by a qualified heating and
air conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be 
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-6575F
Replaces 37-6575E
1423
50D50-842
Universal Direct Spark Control
INSTALLATION INSTRUCTIONS